Skip to Content
Keller-Heartt has Truegard Propylene Glycol Heat Transfer Fluids in both Inhibited and Food Grade! Order Today!
Propylene Glycol Available. Order Today!
Workers wearing protective clothing sort and inspect apples on conveyor belts inside a commercial food processing facility.

Food Plant Lubrication Audit Checklist

Most lubrication findings in a food plant audit aren’t about the lubricant. They come from an approved list that doesn’t match what’s on the shelf, a missing allergen declaration, H2 product creeping into a production zone, or a substitution nobody ran past QA. This free checklist walks through what your auditor will actually ask to see, clause by clause, for SQF, BRCGS, and FSSC 22000 plants. It’s updated for SQF Edition 10, which can be audited starting January 2, 2027. Edition 10 adds formal change management, judges training on effectiveness rather than completion, and escalates repeat findings. Walk it with your maintenance lead, mark your gaps, and use the five fillable templates to build the records an auditor can sample.

Ready to see how your lubrication program measures up? Complete the short form below to get your free copy of the Food Plant Lubrication Audit Checklist, including all five fillable templates and supporting reference guides.

What’s Inside the Audit Checklist

The checklist is organized the way an audit actually runs, so you can find and fix gaps before your auditor does.

Part 1

The Audit Checklist

33 requirements across eight areas: documentation, hazard analysis, lube point controls, storage, supplier controls, training, hygiene clearance, and incident response. Each item lists the clause, the evidence the auditor asks for, and the gap that most often turns into a finding.

Part 2

Five Fillable Templates

A lube point survey and map, approved lubricant list, H1/H2 zoning risk assessment, contractor sign-off, and contamination response procedure.

Part 3

Field Reference

An NSF category quick reference, H1-everywhere vs. zoned comparison, application spec guide, and an eight-step H2-to-H1 changeover plan.

Food safety inspector wearing protective clothing and gloves reviews an inspection checklist beside stainless steel equipment in a food manufacturing facility.

What SQF Edition 10 Changes for Your Lubrication Program

Three changes land directly on lubrication. Switching a lubricant, supplier, or contractor now counts as a change, so you’ll need a documented food safety risk review before you make it. Training is judged on effectiveness, so expect the auditor to ask a technician which grease goes on a specific point. And repeat minor nonconformances can escalate to majors.

None of this is new for well-run programs. It just makes gaps more expensive.

The Gaps Auditors Find Most Often

  • An approved lubricant list copied from a supplier catalog that includes products you don’t use and misses ones you do
  • No allergen declaration on file for food-grade lubricants
  • PM work orders closed out with no record of which product was used
  • H1 and industrial grease stored side by side on the same shelf
  • A distributor’s “equivalent” product going straight to the shelf without a change review

H1, H2, H3: A Quick Reference

  • H1 lubricants are cleared for incidental food contact up to 10 ppm. 
  • H2 lubricants are for equipment with no possibility of food contact. 
  • H3 products are edible oils used as rust preventives on hooks and trolleys. 
  • HT1 covers heat transfer fluids, and 3H covers release agents. 

“Food-grade” is a marketing term, not a category. Auditors accept only the NSF registration as evidence.

Frequently Asked Questions

  • Auditors look for a current, site-specific approved lubricant list, proof of NSF category for every product, allergen documentation, lube point maps and labels, segregated storage, change records for substitutions, and training records. Under SQF Edition 10, they’ll also ask technicians to explain the program, not just show a sign-in sheet.

  • H1 lubricants are NSF registered for incidental food contact, capped at 10 ppm. H2 lubricants are for equipment where there’s no possibility of food contact. Any H2 use in a production area needs a documented risk assessment.

  • No. “Food-grade” is a marketing term. Only the NSF registration letter or a dated NSF White Book listing counts as evidence in an audit.

  • Yes, if the lube point can’t contact product, sits nowhere above or beside exposed product, isn’t in a washdown zone, and wouldn’t release lubricant into a product stream if a seal failed. Many plants simplify by using H1 inside the production building and H2 only for equipment that never enters it.

  • Edition 10 formalizes change management, so product and supplier switches need a documented risk review first. It also evaluates training effectiveness and escalates repeat findings. New certifications and recertifications move to Edition 10 on or after January 2, 2027.

  • Work one line at a time. Map every lube point, check grease and oil compatibility, then flush and purge before relabeling. Document the switch as a change and monitor the converted points for 90 days. Most changeover failures come from compatibility issues, not the new product.